Order No. | Name | Model | D65 | TL84 | F | UV | CWF | TL83 | Voltage |
10118 | Standard light source booth | P120 six light source(220V) | 2pcs | 2pcs | 6pcs | 1pcs | 2pcs | 2pcs | 220V/50Hz |
10818 | Standard light source booth | P120 six light source(115V) | 2pcs | 2pcs | 6pcs | 1pcs | 2pcs | 2pcs | 115V/60Hz |
Light Source | Color viewing booths application | Color temperature(k) | Power(W) |
D65 | International standard Artificial Daylight | 6500 | 36 |
TL84 | Applied to stores in Europe, Japan and China | 4000 | 36 |
CWF | (Cool White Fluorescent) American Standard | 4150 | 36 |
F/A | "Sun-setting Light Yellow" incandescent light source (imitation of sunset) | 2700 | 40 |
UV | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wave length:365nm | 36 |
TL83 | Warm White Fluorescent American Standard | 3000 | 36 |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries.
Our machine is packed by standard export wooden box, it won’t be damaged. We’ve delivered many testing machines abroad by sea or by air without damage.
D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries.
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.
e. Replace completed.