D/8° Handheld Spectrocolorimeter PS2080
The 3nh PS2080 Spectrocolorimeter, also endearingly called the "fat girl", is a top - tier color measurement device renowned for its high - performance capabilities. Unleash precision color analysis with PS2080 spectrocolorimeter – redefine your color standards!
Key Highlights
D/8 optical geometry (diffused illumination with an 8 - degree viewing angle)
SCI/SCE (specular component included / specular component excluded) mode
International standards such as CIE No.15, GB/T 3978, and ISO 7724 - 1
400 - 700 nm full - waveband balanced LED light source
Φ8mm (both flat and tip types), Φ4mm (both flat and tip types), and 1x3mm (both flat and tip types)
CIE LAB, XYZ, Yxy, LCh, CIE LUV, s - RGB, βxy, and DIN Lab99.
D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30), U35, NBF, ID50, ID65
2.8 - inch TFT true - color capacitive touch screen
"Fat girl" is the nickname of PS20 series domestic color spectrometer. It is serious about color measurement and high user satisfaction.
PS2080 "Fat girl" spectrocolorimeter is 3nh developed by CMOS dual-channel spectrocolorimeter sensor, which is not only a colorimeter, but also a spectrocolorimeter,with excellent repeatability and the inner-instrument error. The measurement data is stable, accurate and reliable. with a comfortable and round appearance more people love it. It also has quality management software facilitate quality monitoring and data management.
PS2080 spectrocolorimeter is equipped with six apertures MAV:Φ8mm(flat+tip)、SAV:Φ4mm (flat+tip)、LAV:1x3mm(flat+tip), widely used for plastic electronics, paint ink, textile and garment printing, printing, ceramics and other industries color difference quality control. UV is included for the measurement of fluorescent samples.
PS2080 spectrocolorimeter adopts D/8(diffused illumination, 8-degree viewing angle) which is widely applicable in the world, and SCI/SCE (specular component included/specular component excluded) Synthesis technology. It is suitable for color management and quality control in various industries such as color matching and coating, textile, plastic, food, building materials, cosmetics, etc.
The 400~700nm full waveband balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the spectral loss of white LED in specific waveband, Fluorescent materials can also be easily measured and ensures the measurement speed and accuracy of the measurement results.
High speed and high sensitivity CMOS dual beam splitter sensor makes color data processing more efficient and accurate.
The spectrocolorimeter PS2080 is equipped with an intelligent calibration base. Contact automatic whiteboard calibration is available, professional standard whiteboard reflectivity R%≥95%, good surface uniformity. It has high stability and can obtain repeated and accurate data.
The spectrocolorimeter PS2080 support CIE LAB,XYZ,Yxy, LCh, CIE LUV,S- RGB, βxy, DIN Lab99 Color space and D65, A, C, D50, D55, D75, F1, F2(CWF) ,F3, F4 F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), U35, NBF, ID50, ID65 multiple illumination source, Meet different measurement requirements.
The fitted palm is suitable for continuous detection, which makes you fast and easy to use. An easy to measure device for automatic measurement is added. Which is portable, fast, easy to measure and use.
The built-in camera is used for view taking and positioning. Through real-time view taking, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.
Each PS2080 spectrocolorimeter has been verified and tested. After leaving the factory, each instrument is verified according to the measurement standards of authoritative verification departments, and the measurement data are traceable to the National Metro technical Institute to ensure the authority of the instrument test data.
The built-in camera is used for view taking and positioning. Through real-time view taking, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.
Quality management software Andriod, IOS, Windows, Wechat app and Hongmeng system are applicable to quality monitoring and color data management in various industries. Data the user's color management. compare colon differences, and generate test reports.
Technical Specification
Model | PS2080 spectrocolorimeter |
Optical Geometry | D/8(diffused illumination, 8-degree viewing angle), SCI/SCE (specular component included/specular component excluded) Mode, Comply to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
Characteristic | Adopt CMOS dual beam splitting sensor;Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, also for fluorescence sample measurement. |
Light Source | Combined full spectrum LED light source, UV light source |
Integrating Sphere Size | Φ40mm |
Sensor | CMOS dual beam splitting sensor |
Wavelength Range | 400-700nm |
Measuring Aperture | Six Apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm |
Specular Component | SCI/SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94 ,ΔE*cmc(2:1),ΔE*cmc(1:1) ,ΔE*00, DINΔE99, ΔE(Hunter) |
Other Colorimetric Index | Spectral reflectance, WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313),Metamerism Index Mt,Staining Fastness, Color Fastness,Color Strength, Opacity,555 tone classification, Munsell(C/2)(Partially realize through the PC software /APP software) |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5,F6, F7(DLF),F8,F9,F10(TPL5), F11(TL84),F12(TL83/U30),U35,NBF,ID50,ID65(Partially realize through the PC software /APP software) |
Display | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
Measuring Time | About 1s |
Repeatability | Chromaticity value: MAV/SCI, within ΔE*ab 0.02 (After preheating and correction, the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400nm to 700nm: within 0.18%) |
Inter-instrument Error |
MAV/SCI, Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Displayed Accuracy | 0.01 |
Measured Reflectance Range | 0-200% |
Reflectance Resolution | 0.01% |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Stabilizer position+camera locating |
White Calibration mode | Non-contact automatic calibration |
Dimension | 94X68X188mm |
Weight | About 410g |
Battery | Lithium battery,3.7V,5000mAh,8000 cycles in 8 hours |
Illuminant Life Span | More than 1.2 million measurements over 10 years |
Screen | 2.8 inch TFT true color, Capacitive Touch Screen |
Interface | USB,Bluetooth®5.0 |
Data Storage | Standard 500Pcs, Sample 10000Pcs(One data is able to include SCI/SCE); PC mass storage |
Software support | Andriod,IOS,Windows,Wechat small program, Hongmeng |
Language | Simplified Chinese, English, Traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing),Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, USB Cable, User Guide, SQCX PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, Aperture |
Optional Accessory | USB Micro Printer, Powder Test Box |
Notes | Technical parameters are only for reference, subject to the actual sale of the product |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrocolorimeter
a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.
b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.
e. Replace completed.
Threenh Technology with excellent after sale service, Generally, Our warranty is one years(Additional support period of 3 years). Within the warranty period, we can offer technique support and parts to parts change, necessarily, our engineers may go to your place for better support. Our instrument have professional After-sales Dept. lf you have any technical problem or question with our goods welcome to contact us.
The repeatability is an important parameter for the accuracy of the colorimeter. Threenh Technology portable colorimeter for color measurements tandard deviation ΔE*ab is within 0.03 (Measurement condition: the average value of 30 measurements on the white board at an interval of 3s after calibration). Each colorimeter can pass the qualified inspection before leaving the factory to ensure it conforms to the standard of China Metrology Institute.
The Ideal Accurate and User - Friendly Spectrophotometer for Your Needs
This Spectrophotometer device measures the reflectivity,absorbance, transmittance, and fluorescence of light passing through samples, providing invaluable data for a wide range of applications, provide unrivaled accuracy for reliable results.
Selecting an appropriate spectrophotometer offers significant advantages for precision color analysis and quality control. When choosing an accurate and user - friendly spectrophotometer, consider factors such as wavelength range, sensitivity, sample handling options, and available software features. By investing in the right spectrophotometer, you can streamline your analytical processes, obtain more accurate results, and enhance the overall efficiency of your laboratory or industrial operations.
Choosing the right model—whether portable, benchtop, or inline—aligns technology with specific industry needs, ensuring long-term reliability and optimized color management.