Order No. | Name | Model | D65 | TL84 | F | UV | Voltage |
10106 | Standard light source booth | T60(4) four light source(220V) | 2 pcs | 2 pcs | 4 pcs | 1 pcs | 220V/50Hz |
10806 | Standard light source booth | T60(4) four light source(115V) | 2 pcs | 2 pcs | 4 pcs | 1 pcs | 115V/60Hz |
Light Source | Color viewing booths application | Color temperature(k) | Power(W) |
D65 | International standard Artificial Daylight | 6500 | 18 |
TL84 | Applied to stores in Europe, Japan and China | 4000 | 18 |
CWF | (Cool White Fluorescent) American Standard | 4150 | 18 |
F/A | "Sun-setting Light Yellow" incandescent light source (imitation of sunset) | 2700 | 40 |
UV | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wave length:365nm | 20 |
U30 | Warm White Fluorescent American Standard | 3000 | 18 |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
Opaque liquids and powders can be put into a cuvette for color measurement.
You can choose a colorimters depending on the substrate you are measuring the color of, whether it is opaque, translucent or transparent. In short, you can consider the following factors for choosing the right 3NH colorimeter for your needs: Sample Opacity, Physical Form, Optical Properties needed, Measurement Methods required, Scales and Indices needed, Instrument Standards Conformance (ASTM/ISO/Other), Instrument Geometry, Instrument Performance, Location (laboratory, portability, in-process) and Sample Handling requirements.
By systematically addressing these factors, you can select a colorimeter that optimizes accuracy, efficiency, and value for your specific application.Learn more from our ultimate guide on colorimeter selection. If unsure, consult the 3NH manufacturer for personalized recommendations based on your sample and workflow.
D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries.
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.