Standard SFRplus Chart

This Standard SFRplus Chart Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

The SFRplus test chart can be used with the SFRplus module in Imatest 3.2 or later to measure MTF, lateral chromatic aberration, distortion, tonal response, and color accuracy. The SFRplus module features fully automated region-of-interest detection. The SFRplus chart offers significant advantages over commonly used charts such as the ISO 12233 chart, including 1) much less wasted area, 2) the ability to produce a map of sharpness over the sensor surface, 3) better measurement accuracy due to the lower contrast, and 4) full support for automated testing.

This chart is recommended for most standard testing setups and devices. Choose a size based on your sensor and setup limitations.


Options include:

  • Grid: 5x9 grids are recommended for for typical DSLR formats with aspect ratios of 3:2
  • Paper Size and Active Area Options

    This chart is available in three sizes. It is recommended that the medium sized charts be used to test imaging systems with sensors up to 12 MP, the large charts be used for testing of sensors up to approximately 24 MP, and the extra-large charts be used for sensor sizes above 24 MP.

    Paper Size (Including Margin)

      5x9
    Medium 24
    Large 44
    X-Large 44

    Active Area

    The active area of the chart includes white space above and below the top and bottom distortion bars. It is slightly larger than the printed area, which is bounded by the distortion bars on top and bottom. White space is included in active area because test images of the chart must include this white space in order to enable automated processing in SFRplus software.

      5x9
    Medium 22
    Large 33
    X-Large 42
  • Paper/ink type: Matte paper/ink can be used to reduce reflected light and allow for easier lighting setups
  • Contrast levels: 4:1 contrast ratio for new ISO standard compliance
  • Color chart: a 20 patch color chart.

Our Valued Clients

FAQs About  SFRPlus Test Charts

When detecting color differences, the first factors to consider when selecting a light source include its stability, directionality, lifespan, and the effectiveness of the ultimately obtained spectral curve. The illuminant of a colorimeter is a fixed bulb, such as a tungsten lamp,LED light or a long-life xenon lamp. However, for the same color sample, the results displayed by the instrument vary under different light sources. This is because different light sources cause different absorption and reflection of light on the sample, leading to differences in how both the human eye and the instrument perceive the color. 

In general, the D65 light source is used in the application of coil steel inks for construction. The D65 light source is equivalent to average daylight. Most coil steel inks for construction are used outdoors, and sunlight is regarded as the standard light source in outdoor environments. For household appliance coil steel inks, due to their usage characteristics, they are mostly used indoors. Therefore, the A standard light source is adopted for color measurement of samples based on indoor lighting conditions. The A light source is a carefully specified tungsten light source. Other light sources, such as fluorescent light sources, can be used in many types of applications. For example, some textile factories use fluorescent light sources. Therefore, a reasonable light source should be selected as the mutually recognized measurement method based on actual usage conditions and user requirements. Once agreed upon by both parties, color measurement must be conducted under the same conditions. This helps reduce unnecessary systematic errors and human errors, achieving the optimal consistency in color measurement. 

The 3nh high-precision spectrophotometric colorimeter adopts a combined LED light source with long lifespan and low power consumption, which includes UV (ultraviolet) and UV-excluded options. This design can meet the color difference detection needs of different users and supports the selection of multiple light source modes.

A coating thickness gauge measures coating thickness. It measures coating thickness using three different principles: magnetic induction, eddy current, or ultrasonic. Depending on the coating type and the coating's substrate material, the appropriate principle is selected. For industrial and laboratory use, most of these units deliver accurate, non-invasive readings.


You should not attempt measuring on surfaces that are dirty, oily, or rough, as these surfaces will not provide an accurate reading. Always calibrate the paint thickness tester and make sure to select the proper probe for the substrate as well. Proper execution will bring about consistency as well as trustworthiness to the readings.


a. Check whether the USB cable is connected. If not, please connect it. Check whether the connection is effective. You can re-plug the USB cable to test.

b. If the USB cable is connected well but the interface still displays "USB Disconnect", please re-start the colorimeter and enter "Menu" -"Comm"to start the communication.

c. Change the USB cable or change the USB port in you PC.

Assembling the light booth entails connecting the panels, fixing the light fixtures, fitting the tubes, and calibrating the lights according to our 3nh manufacturer’s instructional and safety guidelines.


Because color perception depends on the following factors: 

Light source - For example, incandescent lamps emit orange light, while fluorescent lamps emit cool white light. Therefore, placing an object near different light sources will result in different perceived colors. 

Observed object - Different types of objects affect color perception differently. Examples include opaque objects, translucent objects, and transparent objects. 

Observer's position - Each observer will describe colors differently based on the position of their eyes. 

Different backgrounds - An object's color will appear duller against a light-colored background than against a dark-colored background. Different directions of light reflection from the object - Light reflected from different directions creates different color perceptions. This is particularly noticeable with metallic objects.

Different directions of light reflection from the object - Light reflected from different directions creates different color perceptions. This is particularly noticeable with metallic objects.

Related SFRPlus Test Charts You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Privacy policy