Revolutionize Color Accuracy with Advanced Precision Technology
The YL4520 Non-contact Benchtop Spectrophotometer is a high-precision color measurement instrument designed for non-contact analysis, ideal for delicate or irregular samples. The All-in-One solution for precise color matching & quality assurance,(with a fixed working distancee) liminates physical contact, preventing sample damage and making it suitable for fragile materials like coatings, textiles, plastics, and electronic components.
Key Highlights
D/8 optical geometry (SCI/SCE) that complies with international standards (e.g., CIE No.15, ASTM E1164)
256-element linear CCD sensor
Spectral range of 400–700 nm
supporting multiple color spaces (e.g., CIE LAB, XYZ, LCH, s-RGB)
Excellent repeatability (ΔEab ≤ 0.08) and inter-instrument agreement (ΔEab ≤ 0.25)
Advanced data management and analysis
Widely used in quality control, R&D, and color matching across industries, it offers a non-destructive solution for precise color evaluation
YL4520 spectrophotometer is a color measuring instrument with 45/0 optical geometry(45 ring-shaped illumination, vertical viewing), to achieve precise non-contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc, which is developed by 3nh independently with independent intellectual property.
YL4520 non-contact benchtop spectrophotometer can be applied for accurate color analysis and transmission in laboratories and R & D industries; it can also be used for accurate color measurement and quality control of automated production lines; it is widely used in cosmetics, irregular metal, fruits and vegetables, food hygiene, plastic electronics, paint and ink, printing, ceramics and other industries. Its unique innovative design can not only provide non-contact measurement scheme directly from the production line, but also ensure stable and high-precision measurement results.
YL4520 non-contact spectrophotometer will not touch the sample in the measurement process, to prevent damage to the sample, but also to avoid cross contamination.
PRODUCT FEATURES
1. non-contact, 45 / 0 geometric optical structure to measure the reflectance and chromaticity of objects
2. The movable measuring head moves up and down according to the actual height of the measured object
3. Large touch screen measurement interface, real-time display of measurement data, to realize more measurement functions
4. Multiple measurement modes (sample, quality control, continuous statistical mode) can be selected to meet the personalized needs
APPLICATION INDUSTRY
45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, paint and ink, printing, ceramics and other industries.
Specification
| Model | YL4520 |
| Optical Geometry | 45/0 method(45 ring-shaped illumination, vertical viewing);Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7,GB 2893,GB/T 18833 |
| Features | 45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, paint and ink, printing, ceramics and other industries. |
| Light Source | Full spectrum LED light |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 400~700nm/10nm output |
| Reflectance Range | 0~200% |
| Measuring Aperture | Φ20mm |
| Non-contact Distance | 7.5mm |
| Sample Height | 0~150mm |
| Distance Adjustment Method | Manual adjustment(test height can be stored) |
| Measuring mode | Sample mode/QC Mode/Continuous statistics mode |
| Locating Method | Camera Locating |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
| Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) |
| Other Colorimetric Index |
WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),TI(ASTM E313,CIE/ISO), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5,F6, F7(DLF),F8,F9,F10(TPL5), F11(TL84),F12(TL83/U30) |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, Chromaticity Graph, Color Simulation, PASS/FAIL Result, Color Offset |
| Measuring Time | About 1.5s |
| Data Storage | Sample mode + QC mode: 30,000; Continuous statistics mode: 10,000 |
|
Repeatability |
Spectral reflectance: Standard deviation within 0.08% Chromaticity value: Within ΔE*ab 0.05 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Inter-instrument Error | Within ΔE*ab 0.25(Average for 12 BCRA Series II color tiles) |
| Measurement Mode | Single Measurement, Average Measurement(2 ~ 99 times) |
| Dimension | 330*250*370mm |
| Weight | About 10 kg |
| Power Supply | DC 24V, 3A Power Adapter |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display Screen | 7" TFT Capacitive Screen-touch Display |
| Data Port | USB/RS-232 |
| Language | Simplified Chinese,Traditional Chinese,English |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation); Altitude < 2000m |
| Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
| Standard Accessory | Power Adapter, User Manual, USB cable, Standard Calibration Board, Black Calibration Cavity, |
| Notes | The specifications are subject to change without notice. |
FAQs About YL4520 Spectrophotometer
The machine used to measure color is primarily called a colorimeter or spectrophotometer.
Spectrophotometer: The most common and precise type. It analyzes light reflected/transmitted by an object across the visible spectrum to quantify color accurately. A spectrophotometer can measure colors on smooth or matte surfaces, as well as textured, glossy, mirror-like surfaces, and special effect colors. It measures the reflected light of a sample at a fixed angle (e.g., 45˚) or captures light reflected at all angles to calculate color measurements that closely match what the human eye perceives. Additionally, similar to how humans flip a sample to view colors from different angles, a spectrophotometer is suitable for measuring a variety of materials and surface characteristics. Widely used in industries like paint, textiles, plastics, Chemicals, Pharmaceuticals, and printing.
Colorimeter: Also called photoelectric integrating colorimeter, a simpler, more cost-effective option. It measures color based on three primary colors (RGB) and is suitable for basic color matching needs. A photoelectric integrating colorimeter is a color measurement device based on the photoelectric integration principle. It directly measures the tristimulus values XYZ of an object's color using three color filters (red, green, blue) and silicon photocells as three sensors. The color measurement principle of this instrument imitates the human eye's mechanism of perceiving the three primary colors (red, green, blue). It corrects the relative spectral sensitivity of the detector through color filters to match the CIE-recommended spectral tristimulus value functions x(λ), y(λ), and z(λ).
Spectrocolorimeter: Combines the functions of spectrophotometers and colorimeters, offering both spectral data and color space values for comprehensive analysis.
Colorimetry is a method that applies color intensity to ascertain the chemical concentrations. It is founded on Beer-Lambert Law, whereby the absorbance at a given wavelength is proportional to the concentration. It is popular in environmental and biochemical testing.
D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries.
Our machine is packed by standard export wooden box, it won’t be damaged. We’ve delivered many testing machines abroad by sea or by air without damage.
Colorimeters or spectrophotometers are used to measure liquid color. They measure light coming through or reflecting off the liquid. Readings can be reported as Lab*, RGB, or absorbance units. So that objective color analysis can be used to control quality, or to measure chemical concentration.
Discuss your project with one of our product specialists:
0086 755 26508999We respond to quote requests within 1 business day.
service@3nh.comSubmit a demo request for the product you're interested in.
Get a Demo